Home > ELECTRICAL > ROUGH ELECTRICAL > LOAD CENTERS > LUG LOAD CENTERS - OUTDOOR
Choose a sub category:
40 AMP 60 AMP 70 AMP
100 AMP 125 AMP 200 AMP
Sort By:
Page of 1
Eaton BR24L70RP Load Center Homeline Square D HOM24L70RB Load Center Eaton BR24L125RP Enclosed Load Center
Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Main lug outdoor load center, 70 A, 2 space and 4 circuit. NEMA type-3R enclosure with a rainproof cover for outdoor use. Class 1170 unit is intended for use in fixed applications and can accommodate overhead or underground feed. Maximum SCCR of 10,000. ANSI certified and UL listed. Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
Eaton BR48L125RP Load Center Eaton BR612L125RP Load Center PowerMark Gold TL240RCU Standard Load Center
Eaton BR Load Center, 120/240 V, 125 A, Number of Phases: 1, Number of Spaces: 4, Number of Poles: 8, Number of Circuits: 8, Breaker/Load Center Type: Main Lug, Interrupt Rating: 10 kAIC, Cable Size: 14 AWG, Wiring Configuration: 3-Wire, Bus Bar Material: Aluminum, Enclosure Type: NEMA 3R, Metal, Gray, Includes: Cover Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality.
PowerMark Gold TL270RCUP Standard Load Center PowerMark TPL412RP Standard Load Center Eaton CH2L70RP Load Center
PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
Siemens EQ W0204ML1060U Load Center GE TL412R1P Standard Load Center Homeline Square D HOM612L100RB Load Center
Single phase, 3-wire, solid neutral, 2 spaces and 4 circuits maximum 1-pole, 1 QP breaker maximum 2-pole, 120/240 VAC. 10,000 AIR. With closure plates, HS style hubs sold separately, uses ECHA075 (694.3559) Hub. One piece plated aluminum bus bar. 100% circuit breaker twist outs. Will not accommodate 2-pole GFCI or circuit breaker with shunt trip. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 deg for bottom feed. Gray enamel finish. CSA and UL listed, complies fully with NEC and UL requirements for Class CTL. 5 in x 8 in x 4-1/4 in. PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. Outdoor main lug load center, 100 A, 6 space and 12 circuits. Can be wired for underground or overhead feeds with a 2-1/2 in hub on the top and a 1-1/2 in knockout on the bottom. NEMA type 3R enclosure resists rain for durable performance. ANSI certified and UL listed.
Siemens EQ W0408ML1125U Load Center Square D QO24L70RB Load Center Square D QO612L100RBCP Load Center
Code-gauge steel enclosure. Single phase, 3-wire, solid neutral, 4 space/8 circuits 1-pole, 2 QP breakers 2-pole, 120/240 VAC. 10,000 AIR. With closure plates, HS-hubs sold separately. One piece plated aluminum bus bar. 100% circuit breaker twist outs. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 A maximum) is back-fed in a branch position and used with main breaker retainer clip No MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 deg for bottom feed. Gray enamel finish. CSA and UL listed, complies fully with NEC and UL requirements for Class CTL. 6 in x 12-1/4 in x 4-1/4 in. Main lug indoor load center, 70 A, 2 space/4 circuits. Intended for overhead or underground feed. 1-1/4 in maximum knockouts in the top and bottom end walls. NEMA 3R enclosure for outdoor use with a factory included cover. Copper bus for conductivity. UL listed. Outdoor main lug load center, 100 A, 6 space 12 circuit. NEMA type 3R enclosure with a rainproof cover. Copper bus bar, accommodates standard QO or QO tandem circuit breakers. ANSI certified and UL listed.
PowerMark Gold TLM612RCU Standard Convertible Load Center Eaton BR816L125RP Load Center LOAD CENTER 125A 8SPACE 16CIR
PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality.
Square D HOM816L125PRB Homeline Main Lug Load Center Siemens EQ W0816ML1125CU Load Center Square D QO816L100RBCP Load Center
Main lug outdoor load center, 125 A 8 space/16 circuit. Convertible to a main breaker. Single-phase load center. Overhead or underground feed options. Plated aluminum bus bar. UL listed. Code-gauge steel enclosure. Single phase, 3-wire, solid neutral, 8 space/16 circuits 1-pole, 4 QP breakers 2-pole, 120/240 VAC. 10,000 AIR. HS-hubs sold separately. One piece copper bus bar, 100% circuit breaker twist outs. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (125 A maximum) is back-fed in a branch position and used with main breaker retainer clip No MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 deg for bottom feed. Gray enamel finish. UL listed, complies fully with NEC and UL requirements for Class CTL. 12-1/8 in x 14-3/4 in x 4-1/4 in. Main lug outdoor load center, 100 A, 8 space/16 circuit, has a 2-1/2 in maximum type B hub in the top end wall, a 1-1/2 in maximum knockout in the bottom end wall and a B-cap covering on the 2 in bushed opening. NEMA type 3R enclosure with a rainproof cover for outdoor use. ANSI certified and UL listed.
PowerMark Gold TLM1212RCUP Standard Convertible Load Center Eaton BR1224L200R Load Center
PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. Eaton Load Center, 120/240 V, 200 A, 1 ph, 12 Spaces, 24 Pole, 24 Circuits, Plug-On Neutral Breaker/Load Center, Bus Bar Material: Aluminum, Bus Bar Rating: 200 A, NEMA 3R Enclosure, Flush, Surface Mounting